Assessing Field and Laboratory Calibration Protocols for the Diviner 2000 Probe in a Range of Soils with Different Textures
View/ Open
Date
2016Author
Giuseppe Provenzano
Giovanni Rallo
Hiba Ghazouani
Metadata
Show full item recordAbstract
Frequency domain reflectometry (FDR) downhole sensors have been increasingly used for soil moisture field monitoring because they allow measurement, even continuously, along a soil profile. Moreover, they can also be installed with minimal soil disturbance around the access tube. The objectives of the paper were to assess the field and laboratory calibration protocols for a FDR capacitance probe (Diviner 2000) for a range of soils characterized by different particle size distributions and shrink/swell potential and to propose a practical and effective protocol on the basis of undisturbed soil samples, accounting for soil shrinkage/swelling processes characterizing swelling clay soils. The experiments showed that on coarse-textured soils, field calibration under wet, moist, and dry conditions allows estimations of the volumetric soil water content, with root-mean-square error (RMSE) values always lower than