Show simple item record

dc.contributor.authorRaymond A. LeClair
dc.date.accessioned2017-05-08T22:27:36Z
dc.date.available2017-05-08T22:27:36Z
dc.date.copyrightSeptember 1989
dc.date.issued1989
dc.identifier.other%28asce%290733-9399%281989%29115%3A9%282011%29.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/80964
dc.description.abstractAn upper bound to the mechanical power loss in wire ropes bent over a sheave is determined by considering the geometry of a deformed helical wire and using results from the linear theory of wire rope. Results are presented for a wire strand in which the outer wires contact the center wire and in which the outer wires contact each other. The results indicate that the former type of strand exhibits a smaller power loss and that this loss can be reduced by appropriate choice of wire diameters. The variation of the ratio of power loss due to friction to transmitted power, with pertinent design variables, is presented.
dc.publisherAmerican Society of Civil Engineers
dc.titleUpper Bound to Mechanical Power Transmission Losses in Wire Rope
dc.typeJournal Paper
dc.journal.volume115
dc.journal.issue9
dc.journal.titleJournal of Engineering Mechanics
dc.identifier.doi10.1061/(ASCE)0733-9399(1989)115:9(2011)
dc.treeJournal of Engineering Mechanics:;1989:;Volume ( 115 ):;issue: 009
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record