• Login
    View Item 
    •   DSpace Home
    • ASCE
    • Journal of Structural Engineering
    • View Item
    •   DSpace Home
    • ASCE
    • Journal of Structural Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Strain Rate Effect on Development Length of Steel Reinforcement

    Thumbnail
    View/Open
    45738028.pdf (5.367Mb)
    Date
    2015
    Author
    Lauren Toikka
    Abass Braimah
    Ghani Razaqpur
    Simon Foo
    Metadata
    Show full item record
    Abstract
    Accidental or premeditated explosions have detrimental effects on the infrastructure near the center of explosion and pose major threats to human life. Thus, research is currently underway to study the effects of explosions on infrastructure systems with the ultimate goal of minimizing infrastructure damage and saving lives. Because reinforced concrete is the most common building material used in blast-resistant infrastructure design and construction, understanding the effect of blast loads on reinforced concrete components is essential to reaching this goal. The prevailing design philosophy for blast-resistant structures is energy dissipation through reinforcement yielding (ductility) and large bending deformations without the incidence of nonductile failure modes such as shear and bond. However, information regarding the bond behavior and strength of steel reinforcement–concrete bonds under blast loads is rather scant; therefore, this paper reports on an experimental program designed to investigate the strain rate effect on steel reinforcement–concrete bond. Reinforced concrete beams longitudinally reinforced with 15M, 20M, or 25M were tested in a shock tube under simulated blast loading. The test results show that high strain rate increases the steel reinforcement–concrete bond strength and thus, that the static load development lengths of these bars are adequate for developing their dynamic yield strengths at high strain rate. The dynamic increase factor for bond stress is determined to be 1.11 for 15M, 2.24 for 20M, and 3.68 for 25M bar.
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/80937
    Collections
    • Journal of Structural Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV