Show simple item record

dc.contributor.authorF. El Meski
dc.contributor.authorM. Harajli
dc.date.accessioned2017-05-08T22:27:10Z
dc.date.available2017-05-08T22:27:10Z
dc.date.copyrightJune 2015
dc.date.issued2015
dc.identifier.other45497738.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/80854
dc.description.abstractThis paper presents a synthesis of the results of a broad experimental and analytical research program undertaken for evaluating the flexural behavior of unbonded posttensioned prestressed concrete (PC) members when strengthened using external fiber-reinforced polymer (FRP) composites. In the experimental part of the investigation, the findings of which were reported earlier, 24 specimens were tested. The test variables included span-to-depth ratio, area of unbonded prestressing steel, area of FRP reinforcement, and profile of the prestressing tendons. An additional 12 companion bonded PC and reinforced concrete (RC) specimens having the same design parameters as the unbonded specimens were also tested for comparison. In the analytical part, numerical nonlinear analysis was carried out for analyzing the flexural behavior of FRP strengthened unbonded PC members and for regenerating the response of the specimens tested in the experimental part of the investigation. Also, a general design oriented model was developed, vis à vis the test results, for calculating the flexural capacity of FRP-strengthened posttensioned members with an internal or external unbonded tendon system. The procedure is consistent with the approach proposed in a standard-setting report for reinforced concrete or bonded prestressed concrete members, and is applicable for both simply supported and continuous members. A flow chart was developed for illustrating the use of the proposed design procedure.
dc.publisherAmerican Society of Civil Engineers
dc.titleEvaluation of the Flexural Response of CFRP-Strengthened Unbonded Posttensioned Members
dc.typeJournal Paper
dc.journal.volume19
dc.journal.issue3
dc.journal.titleJournal of Composites for Construction
dc.identifier.doi10.1061/(ASCE)CC.1943-5614.0000516
dc.treeJournal of Composites for Construction:;2015:;Volume ( 019 ):;issue: 003
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record