dc.description.abstractThis experimental study focuses on the design and spacing of splices of fiber-reinforced polymer (FRP) stay-in-place structural forms used in concrete bridge decks. The ribbed FRP panels, which span the gap between girders, are typically of limited width, and therefore are spliced by overlapping. A total of 23 auxiliary lap splice tension tests addressed various bond systems including adhesive and/or mechanical fasteners of various diameters and spacing. Seven scaled bridge deck systems were built with FRP panels of various widths, some with bonded splices and some with no bond at all at the overlap region. The study showed that using narrow FRP plates of small width-to-deck thickness (
dc.publisherAmerican Society of Civil Engineers
dc.titleSplices of FRP Stay-in-Place Structural Forms in Concrete Bridge Decks
dc.typeJournal Paper
dc.journal.volume18
dc.journal.issue4
dc.journal.titleJournal of Composites for Construction
dc.identifier.doi10.1061/(ASCE)CC.1943-5614.0000455
dc.treeJournal of Composites for Construction:;2014:;Volume ( 018 ):;issue: 004