• Login
    View Item 
    •   DSpace Home
    • ASCE
    • Journal of Structural Engineering
    • View Item
    •   DSpace Home
    • ASCE
    • Journal of Structural Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Panel Zone Shear Behavior of Through-Flange Connections for Steel Beams to Circular Concrete-Filled Steel Tubular Columns

    Thumbnail
    View/Open
    45289988.pdf (31.62Mb)
    Date
    2015
    Author
    Yu-Chen Ou
    Ngoc-Minh Tran
    Cheng-Cheng Chen
    Hung-Jen Lee
    Metadata
    Show full item record
    Abstract
    This research investigated the panel zone shear behavior of a proposed through-flange connection for steel beams to circular concrete-filled steel tubular (CFT) columns. Four exterior beam-column specimens were designed and tested using cyclic loading applied to the beam end. Three design variables were examined: concrete infill in the column tube, stiffeners to the column tube in the panel zone, and the width of the through-flange plates. Test results showed significant panel zone shear yielding for all specimens. Failure of the specimens was caused by fracture of the column tube near the through-flange plates and crushing of concrete at the stiffener side in the panel zone if concrete infill was present. The use of concrete infill, stiffeners, and 25% wider through-flange plates increased the peak applied load by 156, 7, and 14%, respectively. A model that considers crushing of concrete at the stiffener side as failure mode was proposed to calculate the panel zone shear strength contribution from concrete. If confined concrete strength was used, the panel zone shear strengths calculated with concrete contribution based on the proposed model were, on average, 8% more conservative than the test results. If unconfined concrete strength was used, the calculated panel zone shear strengths were, on average, 63% more conservative than the test results. The panel zone shear strengths calculated with concrete contribution based on the ACI 318 and ACI 352 R methods were, on average, 46 and 39% more conservative than the test results, respectively.
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/80762
    Collections
    • Journal of Structural Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV