Show simple item record

dc.contributor.authorAlok Goyal
dc.contributor.authorAnil K. Chopra
dc.date.accessioned2017-05-08T22:25:41Z
dc.date.available2017-05-08T22:25:41Z
dc.date.copyrightJuly 1989
dc.date.issued1989
dc.identifier.other%28asce%290733-9399%281989%29115%3A7%281393%29.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/80464
dc.description.abstractFor the preliminary phase of design or safety evaluation of intake‐outlet towers, the hydrodynamic interaction effects can be most simply represented in earthquake response analysis by added hydrodynamic mass distributed over the height of the tower. A simplified procedure is developed to evaluate the added hydrodynamic mass for towers of arbitrary cross section, having two axes of symmetry and dimensions varying along the height. It is demonstrated that the added mass associated with surrounding (outside) water or inside water can be determined to a useful degree of accuracy without rigorous three‐dimensional analysis of the two fluid domains. Standard data are presented for convenient implementation of the simplified procedures developed in this paper.
dc.publisherAmerican Society of Civil Engineers
dc.titleSimplified Evaluation of Added Hydrodynamic Mass for Intake Towers
dc.typeJournal Paper
dc.journal.volume115
dc.journal.issue7
dc.journal.titleJournal of Engineering Mechanics
dc.identifier.doi10.1061/(ASCE)0733-9399(1989)115:7(1393)
dc.treeJournal of Engineering Mechanics:;1989:;Volume ( 115 ):;issue: 007
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record