Show simple item record

dc.contributor.authorH. C. Chan
dc.contributor.authorJ. S. Kuang
dc.date.accessioned2017-05-08T22:24:21Z
dc.date.available2017-05-08T22:24:21Z
dc.date.copyrightApril 1989
dc.date.issued1989
dc.identifier.other%28asce%290733-9399%281989%29115%3A4%28689%29.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/79875
dc.description.abstractAn analytical method for investigating the effect of a stiffening beam on coupled shear walls is presented. Closed‐form solutions to the problem based on the continuous medium technique are obtained with the position of the stiffening beam placed somewhere along the structural height as a variable. The results of analysis for a typical structure demonstrate that great beneficial effects on the structural behavior can be achieved by installing a stiffening beam at about 0.2 to 0.5 of the structural height in the coupled shear walls, depending on whether the condition for the minimum value of the laminar shear, the base moment, or the top deflection is to be made.
dc.publisherAmerican Society of Civil Engineers
dc.titleStiffened Coupled Shear Walls
dc.typeJournal Paper
dc.journal.volume115
dc.journal.issue4
dc.journal.titleJournal of Engineering Mechanics
dc.identifier.doi10.1061/(ASCE)0733-9399(1989)115:4(689)
dc.treeJournal of Engineering Mechanics:;1989:;Volume ( 115 ):;issue: 004
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record