Show simple item record

dc.contributor.authorG. X. Guan
dc.contributor.authorC. J. Burgoyne
dc.contributor.authorM. Achintha
dc.date.accessioned2017-05-08T22:24:12Z
dc.date.available2017-05-08T22:24:12Z
dc.date.copyrightDecember 2014
dc.date.issued2014
dc.identifier.other44093615.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/79807
dc.description.abstractFiber-reinforced polymer (FRP) plate debonding is commonly caused by the fracturing of concrete, but few studies of fracture debonding models exist, from which the failure load of the concrete cover layer can be evaluated. This paper presents a parametric study for plate end debonding using the global energy balance approach (GEBA), which has been proposed recently for determining the structure-debonding load. GEBA determines the debonding load using moment-curvature (
dc.publisherAmerican Society of Civil Engineers
dc.titleParametric Study of FRP Plate Debonding Using Global Energy Balance
dc.typeJournal Paper
dc.journal.volume18
dc.journal.issue6
dc.journal.titleJournal of Composites for Construction
dc.identifier.doi10.1061/(ASCE)CC.1943-5614.0000474
dc.treeJournal of Composites for Construction:;2014:;Volume ( 018 ):;issue: 006
dc.contenttypeFulltext