• Login
    View Item 
    •   DSpace Home
    • ASCE
    • Journal of Bridge Engineering
    • View Item
    •   DSpace Home
    • ASCE
    • Journal of Bridge Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Anchorage Capacity of Concrete Bridge Barriers Reinforced with GFRP Bars with Headed Ends

    Thumbnail
    View/Open
    44024844.pdf (3.971Mb)
    Date
    2014
    Author
    Hossein
    Azimi
    Khaled
    Sennah
    Ekaterina
    Tropynina
    Sergiy
    Goremykin
    Stefan
    Lucic
    Meimei
    Lam
    Metadata
    Show full item record
    Abstract
    An experimental program was conducted to investigate the application of headed glass fiber-reinforced polymer (GFRP) ribbed bars at the barrier wall-deck anchorage. Six full-scale barrier models of 1,200 mm in length were erected and tested under static monotonic loading to determine their ultimate load-carrying capacities and failure modes with respect to the barrier wall-deck anchorage. Four PL-2 barrier specimens were cast: two of them were of tapered face and the other two specimens were of parapet type with constant thickness. Each set had a steel-reinforced specimen as the control model and a GFRP-reinforced specimen. In addition, two PL-3 GFRP-reinforced specimens were erected with different spacing of GFRP bars. Each specimen was loaded laterally until collapse. This paper presents the results from these tests in the form of crack pattern, deflection history, and ultimate load-carrying capacity. Experimental results were compared with the design values specified in the Canadian bridge code for barrier anchorage into the deck slabs, showing a large margin of safety for the proposed GFRP-reinforced barriers. In addition, a parametric study was undertaken using finite-element analysis to investigate the applicability of resultant design loads prescribed by the Canadian bridge code for the design of the barrier wall-deck anchorage. The key parameters considered in this study were deck overhang length and thickness and barrier length. The data generated from this parametric study were used to develop set of empirical expressions for the factored applied moment at the barrier-deck interface, as well as the factored tensile force required to design the deck slab cantilever.
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/79720
    Collections
    • Journal of Bridge Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV