Show simple item record

dc.contributor.authorTakeru Igusa
dc.contributor.authorArmen Der Kiureghian
dc.date.accessioned2017-05-08T22:21:40Z
dc.date.available2017-05-08T22:21:40Z
dc.date.copyrightAugust 1988
dc.date.issued1988
dc.identifier.other%28asce%290733-9399%281988%29114%3A8%281375%29.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/78675
dc.description.abstractAn efficient and accurate method is presented for dynamic analysis of tertiary subsystems mounted on primary‐secondary systems, such as control devices attached to piping in nuclear power plants. Modal properties, such as natural frequencies, damping ratios, and mode shapes, of the composite primary‐secondary‐tertiary system are derived in terms of the known subsystem properties, employing previously developed modal synthesis and perturbation results for primary‐secondary systems, which are extended here to subsystems with non‐classical damping. The method is direct in that the response of the tertiary subsystem is obtained in terms of the input excitation without the need to generate intermediate results, such as floor response spectra. Important effects of tuning, interaction, nonclassical damping, and spatial coupling are fully accounted for. The paper also presents an in‐depth analysis of the conditions and effects of tuning in primary‐secondary‐tertiary systems.
dc.publisherAmerican Society of Civil Engineers
dc.titleDynamic Response of Tertiary Subsystems
dc.typeJournal Paper
dc.journal.volume114
dc.journal.issue8
dc.journal.titleJournal of Engineering Mechanics
dc.identifier.doi10.1061/(ASCE)0733-9399(1988)114:8(1375)
dc.treeJournal of Engineering Mechanics:;1988:;Volume ( 114 ):;issue: 008
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record