Show simple item record

dc.contributor.authorG. C. Mays
dc.contributor.authorJ. G. Hetherington
dc.contributor.authorT. A. Rose
dc.date.accessioned2017-05-08T22:21:18Z
dc.date.available2017-05-08T22:21:18Z
dc.date.copyrightDecember 1999
dc.date.issued1999
dc.identifier.other43035973.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/78519
dc.description.abstractThe assessment of reinforced concrete wall panels subject to blast loading may be based upon the formulation of a dynamic, ultimate flexural resistance-deflection function for the element. With the exception of situations in which the explosion occurs at very close proximity to the panel, the ultimate blast resistance is normally based upon the static resistance, which is subsequently modified for dynamic effects. A previous paper by the writers has shown that the static resistance of panels with door and window openings may be determined by the application of a modification factor to the resistance of a similar panel with no openings. In this technical note the method is validated against the results of blast trials using model reinforced concrete wall panels with openings subject to impulsive loading. It is shown that the impulsive blast capacity of wall panels with openings may be determined by applying a factor to the static ultimate resistance.
dc.publisherAmerican Society of Civil Engineers
dc.titleResponse to Blast Loading of Concrete Wall Panels with Openings
dc.typeJournal Paper
dc.journal.volume125
dc.journal.issue12
dc.journal.titleJournal of Structural Engineering
dc.identifier.doi10.1061/(ASCE)0733-9445(1999)125:12(1448)
dc.treeJournal of Structural Engineering:;1999:;Volume ( 125 ):;issue: 012
dc.contenttypeFulltext