Show simple item record

dc.contributor.authorNicholas E. Wierschem
dc.contributor.authorJie Luo
dc.contributor.authorMohammad AL-Shudeifat
dc.contributor.authorSean Hubbard
dc.contributor.authorRichard Ott
dc.contributor.authorLarry A. Fahnestock
dc.contributor.authorD. Dane Quinn
dc.contributor.authorD. Michael McFarland
dc.contributor.authorB. F. Spencer Jr.
dc.contributor.authorAlexander Vakakis
dc.contributor.authorLawrence A. Bergman
dc.date.accessioned2017-05-08T22:19:58Z
dc.date.available2017-05-08T22:19:58Z
dc.date.copyrightJune 2014
dc.date.issued2014
dc.identifier.other41216786.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/77894
dc.description.abstractThe nonlinear energy sink (NES) is a fully passive attachment used to rapidly dissipate a significant portion of energy induced in a linear primary structure to which it is attached. In this study, the performance of a Type III NES in reducing the response of a large primary structure when subjected to a shock-type loading is evaluated experimentally. The Type III NES is a two-degree-of-freedom device comprising two relatively lightweight masses in series coupled together and to the primary structure through essentially nonlinear (i.e., nonlinearizable) stiffness elements. The essential stiffness nonlinearity of the NES and the corresponding lack of preferential resonance frequencies enable it to resonantly interact with multiple structural modes over broad frequency and energy ranges. Hence a local NES can induce global effects in the dynamics of the structure to which it is attached. In this study, and for the first time, specially shaped polyurethane bumpers are employed for realizing these essentially nonlinear stiffness elements of the Type III NES. Measures calculated from the experiments in this study, such as the effective damping of the primary structure, indicate the ability of the NES to dissipate energy and reduce the response of the primary structure over a wide range of magnitudes of a shock loading. Good agreement between numerical predictions and experimental observations validates the identified model of the NES.
dc.publisherAmerican Society of Civil Engineers
dc.titleExperimental Testing and Numerical Simulation of a Six-Story Structure Incorporating Two-Degree-of-Freedom Nonlinear Energy Sink
dc.typeJournal Paper
dc.journal.volume140
dc.journal.issue6
dc.journal.titleJournal of Structural Engineering
dc.identifier.doi10.1061/(ASCE)ST.1943-541X.0000978
dc.treeJournal of Structural Engineering:;2014:;Volume ( 140 ):;issue: 006
dc.contenttypeFulltext