• Login
    View Item 
    •   DSpace Home
    • ASCE
    • Journal of Architectural Engineering
    • View Item
    •   DSpace Home
    • ASCE
    • Journal of Architectural Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Wind Uplift Capacity of Foam-Retrofitted Roof Sheathing Panels Subjected to Rainwater Intrusion

    Thumbnail
    View/Open
    40437239.pdf (1.937Mb)
    Date
    2014
    Author
    David O.
    Prevatt
    Kenton E.
    McBride
    David B.
    Roueche
    Forrest J.
    Masters
    Metadata
    Show full item record
    Abstract
    Widespread damage to residential roofing systems during Hurricane Andrew in 1992 highlighted the structural inadequacy of wood roof sheathing attachment in existing Florida homes. Prior research found that retrofitting wood decks with closed-cell spray-applied polyurethane foam (ccSPF) could provide adequate wind resistance to pre-1994 roofs. However, it is unknown whether this retrofit method increases the potential for moisture to accumulate in the roof sheathing, and if so, what effect this has on the strength of the bond between the ccSPF and the wood substrate. Five full-scale roofs were subjected to natural weathering for 3 months, and 131 small-scale laboratory samples of ccSPF bonded to wood sheathing were intermittently sprayed with water and stored in a high-humidity environment for up to 16 weeks. These tests enabled systematic assessment of the effects of water leakage on ccSPF-retrofitted roof structures. The attic roofs were retrofitted with two ccSPF configurations and covered with three-tab asphalt-shingle roofing subjected to extreme leakage conditions. A control attic roof was not retrofitted with ccSPF. Moisture content and temperature were continuously monitored in the wood truss members of the roofs over 3 months of exposure to both natural and simulated rainfall conditions. At the conclusion of the exposure period, sheathing panels were harvested and subjected to wind uplift structural tests. Tensile tests were conducted on the small-scale samples after 0, 1, 2, 4, 8, 12, and 16 weeks of exposure. The results demonstrated that with extreme leakage conditions, ccSPF-retrofitted roofs experienced significant moisture buildup in the wood substrates. However, the ccSPF-retrofitted sheathing panels maintained high wind uplift failure capacities. The tensile tests on small-scale samples demonstrated as much as 54% reduction in tensile strength of the wood-ccSPF bond with time as a result of moisture-induced bond degradation, although the strength of this bond after 16-week exposure remained above design wind pressures by a minimum factor of 3.75.
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/77251
    Collections
    • Journal of Architectural Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV