Show simple item record

dc.contributor.authorX. Wang
dc.contributor.authorE. Pantoli
dc.contributor.authorT. C. Hutchinson
dc.contributor.authorJ. I. Restrepo
dc.contributor.authorR. L. Wood
dc.contributor.authorM. S. Hoehler
dc.contributor.authorP. Grzesik
dc.contributor.authorF. H. Sesma
dc.date.accessioned2017-05-08T22:15:39Z
dc.date.available2017-05-08T22:15:39Z
dc.date.copyrightOctober 2015
dc.date.issued2015
dc.identifier.other40018376.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/75426
dc.description.abstractThis paper presents the seismic performance of two types of cold-formed steel wall systems as characterized during a full-scale five-story building shake table test program: (1) an exterior architectural façade, which spanned the lower three levels of the building, and (2) interior partition wall systems distributed at all levels of the building. The test building was subjected to a suite of earthquake input motions of increasing intensity, first while the building was isolated at its base, and subsequently while it was fixed to the shake table platen. This paper presents the observed physical and measured responses for the two cold-formed steel wall systems and in particular associates physical damage states with measured drift demands in the building. The tests illustrate damage mechanisms for cold-formed steel wall systems when used in architectural façades and highlights areas that should be given particular consideration during seismic design.
dc.publisherAmerican Society of Civil Engineers
dc.titleSeismic Performance of Cold-Formed Steel Wall Systems in a Full-Scale Building
dc.typeJournal Paper
dc.journal.volume141
dc.journal.issue10
dc.journal.titleJournal of Structural Engineering
dc.identifier.doi10.1061/(ASCE)ST.1943-541X.0001245
dc.treeJournal of Structural Engineering:;2015:;Volume ( 141 ):;issue: 010
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)