Show simple item record

dc.contributor.authorRyan D. Stewart
dc.contributor.authorDaniel S. Moreno
dc.contributor.authorJohn S. Selker
dc.date.accessioned2017-05-08T22:14:16Z
dc.date.available2017-05-08T22:14:16Z
dc.date.copyrightOctober 2015
dc.date.issued2015
dc.identifier.other39944885.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/74719
dc.description.abstractEfforts to prevent temperature increases in streams and rivers have led to regulation of the maximum permissible temperature for wastewater discharges. Hyporheic discharge treatment, where warm wastewater is allowed to infiltrate into the soil and percolate toward the stream, has been proposed as an alternative management practice, potentially providing increased streamflow at decreased temperature. To assess the feasibility of such a system, a pilot study was performed in which groundwater level, temperature, and chemistry were monitored to characterize percolation from a 0.15-ha infiltration wetland. The temperature patterns suggested that water seepage rates exceeded
dc.publisherAmerican Society of Civil Engineers
dc.titleQuantification and Scaling of Infiltration and Percolation from a Constructed Wetland
dc.typeJournal Paper
dc.journal.volume20
dc.journal.issue10
dc.journal.titleJournal of Hydrologic Engineering
dc.identifier.doi10.1061/(ASCE)HE.1943-5584.0001164
dc.treeJournal of Hydrologic Engineering:;2015:;Volume ( 020 ):;issue: 010
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record