Show simple item record

dc.contributor.authorAmin Saleh Aly
dc.date.accessioned2017-05-08T22:09:20Z
dc.date.available2017-05-08T22:09:20Z
dc.date.copyrightOctober 1993
dc.date.issued1993
dc.identifier.other35230374.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/72465
dc.description.abstractThe buckling loads, buckling lengths, and P‐delta effects for pitched roof frames with different loading arrangements are examined. Results are compared to some common and internationally known code results. It was found that the load distribution significantly affects the buckling loads and hence the buckling lengths and the magnified (or added) moments. This paper clarifies a defect in some national building codes and encourages the use of computers in determining the buckling loads and/or the magnified moments. It is worth noting that although the program suggested is simple, it is robust and could be used to trace the large deformation characteristics of frames.
dc.publisherAmerican Society of Civil Engineers
dc.titleStability of Pitched‐Roof Frames in National Building Codes
dc.typeJournal Paper
dc.journal.volume119
dc.journal.issue10
dc.journal.titleJournal of Structural Engineering
dc.identifier.doi10.1061/(ASCE)0733-9445(1993)119:10(3090)
dc.treeJournal of Structural Engineering:;1993:;Volume ( 119 ):;issue: 010
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record