Show simple item record

dc.contributor.authorJ. P. Firmo
dc.contributor.authorJ. R. Correia
dc.contributor.authorD. Pitta
dc.contributor.authorC. Tiago
dc.contributor.authorM. R. T. Arruda
dc.date.accessioned2017-05-08T22:08:31Z
dc.date.available2017-05-08T22:08:31Z
dc.date.copyrightAugust 2015
dc.date.issued2015
dc.identifier.other32490256.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/72171
dc.description.abstractThis paper presents an experimental study concerning the bond behavior at high temperatures between concrete and carbon fiber–reinforced polymer (CFRP) strips installed according to the near-surface-mounted (NSM) technique. Double-lap shear tests were performed on concrete blocks strengthened with CFRP strips installed into slits and bonded with either an epoxy adhesive (series EP) or a mixed grout composed of epoxy and cement binders (series MG). Specimens were first heated up to predefined temperatures (from 20 to 150°C, measured in the adhesive) and then were loaded up to failure. The obtained results allow drawing the following conclusions: (1) the axial strains along the bonded length became closer to linear (at high temperature) because of the softening (glass transition) of the bonding materials; (2) the effective bond length increased for elevated temperature; (3) the bond-slip curves exhibited considerable and consistent stiffness and maximum shear stress reduction with temperature; (4) the failure modes in series EP changed from cohesive (in the concrete) at ambient temperature to adhesive (at the CFRP-adhesive interface) at elevated temperatures; and (5) the bond strength was considerably reduced with temperature. The mixed grout, although providing similar bond strength at ambient temperature and in spite of containing cement binders, suffered much higher performance reduction with elevated temperature compared to epoxy. With this latter adhesive, very high residual strength was measured for temperatures well above the
dc.publisherAmerican Society of Civil Engineers
dc.titleBond Behavior between Near-Surface-Mounted CFRP Strips and Concrete at High Temperatures
dc.typeJournal Paper
dc.journal.volume19
dc.journal.issue4
dc.journal.titleJournal of Composites for Construction
dc.identifier.doi10.1061/(ASCE)CC.1943-5614.0000535
dc.treeJournal of Composites for Construction:;2015:;Volume ( 019 ):;issue: 004
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record