Show simple item record

dc.contributor.authorHugo Corres
dc.contributor.authorPeiretti
dc.contributor.authorJavier Ezeberry
dc.contributor.authorParrotta
dc.contributor.authorAmets Berecibar
dc.contributor.authorOregui
dc.contributor.authorAlejandro Perez
dc.contributor.authorCaldentey
dc.contributor.authorFreddy Ariñez
dc.contributor.authorFernandez
dc.date.accessioned2017-05-08T22:05:30Z
dc.date.available2017-05-08T22:05:30Z
dc.date.copyrightOctober 2014
dc.date.issued2014
dc.identifier.other23109735.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/71098
dc.description.abstractThis paper presents extensive temperature measurements obtained during a period of 4 years in an integral solid slab prestressed concrete bridge deck. There is very little experimental information available for this bridge typology. The quality of the measured temperature data are validated by comparing experimentally measured displacements at the ends of the bridge with theoretical displacements determined with the recorded temperature components. The measured temperatures are also compared with common design parameters made considering the specifications for thermal actions proposed by Eurocode 1. The results corroborate that the Eurocode 1 formulations are generally adequate to represent thermal actions on bridges; however, it may need to be complemented to define maximum and minimum temperatures for bridges in locations with daily temperature variations greater than 10°C.
dc.publisherAmerican Society of Civil Engineers
dc.titleExperimental Study of Thermal Actions on a Solid Slab Concrete Deck Bridge and Comparison with Eurocode 1
dc.typeJournal Paper
dc.journal.volume19
dc.journal.issue10
dc.journal.titleJournal of Bridge Engineering
dc.identifier.doi10.1061/(ASCE)BE.1943-5592.0000614
dc.treeJournal of Bridge Engineering:;2014:;Volume ( 019 ):;issue: 010