dc.description.abstractThe behavior of single plate shear connections in steel structures is studied in this paper. Based on the analyses of the test data, new design procedures are developed and presented. The research and the design procedures presented here have formed the basis of the current AISC design procedures in the AISC manuals. Research indicated that the connections designed according to the proposed method possess sufficient shear strength, rotational flexibility, and ductility and can be categorized as simple (pin) connections. In the study, six failure modes were established, and design equations were formulated and proposed for each limit state of failure.
dc.publisherAmerican Society of Civil Engineers
dc.titleBehavior and Design of Steel Single Plate Shear Connections
dc.typeJournal Paper
dc.journal.volume119
dc.journal.issue8
dc.journal.titleJournal of Structural Engineering
dc.identifier.doi10.1061/(ASCE)0733-9445(1993)119:8(2421)
dc.treeJournal of Structural Engineering:;1993:;Volume ( 119 ):;issue: 008
dc.contenttypeFulltext