Show simple item record

dc.contributor.authorCao Guo-hui
dc.contributor.authorFang Zhi
dc.date.accessioned2017-05-08T22:04:52Z
dc.date.available2017-05-08T22:04:52Z
dc.date.copyrightJuly 2007
dc.date.issued2007
dc.identifier.otherjhtrcq%2E0000165.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/70717
dc.description.abstractA concrete thin-walled box girder prestressed with external CFRP tendons has been made, and tested in the course of CFRP tendons tensing until concrete cracking. Prestressing loss and some behaviors under uniform load such as stress and strain distribution, effective width coefficient of compressive top flange, deflection, crack patterns at mid-section, and stress variety of CFRP tendons have been studied. Experiments show that the box girder perform well against cracking and deformation, with effective width coefficient of compressive top flange increased by less than 5% due to concrete cracking. The reliable experimental basis will be helpful to the application of externally prestressed CFRP tendons in concrete box girder.
dc.publisherAmerican Society of Civil Engineers
dc.titleExperimental Study on Behaviour of Concrete Box Girder Prestressed with External CFRP Tendons
dc.typeJournal Paper
dc.journal.volume2
dc.journal.issue1
dc.journal.titleJournal of Highway and Transportation Research and Development (English Edition)
dc.identifier.doi10.1061/JHTRCQ.0000165
dc.treeJournal of Highway and Transportation Research and Development (English Edition):;2007:;Volume ( 002 ):;issue: 001
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record