Show simple item record

dc.contributor.authorMurray J. Morrison
dc.contributor.authorGregory A. Kopp
dc.date.accessioned2017-05-08T22:01:11Z
dc.date.available2017-05-08T22:01:11Z
dc.date.copyrightMarch 2010
dc.date.issued2010
dc.identifier.other%28asce%29su%2E1943-5428%2E0000045.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/68876
dc.description.abstractThe current investigation extends the previous work in calculating components and cladding loads for standing seam metal roof clips. It was found that the ASCE 7-05 wind loads for these clips are conservative, while several other studies have shown that the ASCE 7-05 is unconservative when compared to integrated wind tunnel pressure data. The current note resolves this contradiction, showing that the observed conservatism is primarily due to the fact that the critical clips are not located in the worst aerodynamic region of the roof.
dc.publisherAmerican Society of Civil Engineers
dc.titleAnalysis of Wind-Induced Clip Loads on Standing Seam Metal Roofs
dc.typeJournal Paper
dc.journal.volume136
dc.journal.issue3
dc.journal.titleJournal of Structural Engineering
dc.identifier.doi10.1061/(ASCE)ST.1943-541X.118
dc.treeJournal of Structural Engineering:;2010:;Volume ( 136 ):;issue: 003
dc.contenttypeFulltext