Show simple item record

dc.contributor.authorThanh-Phuong Pham
dc.contributor.authorBing Li
dc.date.accessioned2017-05-08T22:00:57Z
dc.date.available2017-05-08T22:00:57Z
dc.date.copyrightMarch 2014
dc.date.issued2014
dc.identifier.other%28asce%29st%2E1943-541x%2E0000903.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/68798
dc.description.abstractMany earthquake reconnaissance studies have revealed a unique splitting failure mode of reinforced concrete (RC) columns that has yet to be fully elucidated. Most available shear strength models in the current codes are established based on the concept of a diagonal shear plane through which shear force must be transferred; this concept might not be as applicable to RC columns that failed by vertical cracks, or via splitting failure from an earthquake. In this study, an alternative load-transferring path is proposed that not only explains the failure mechanism, but also allows the estimation of shear strength of the test specimens. Experimental observations from 17 RC columns that underwent splitting failure were used to validate the proposed model. To enhance the applicability of the model, it was corroborated further with 89 short columns screened from existing literature. The validations showed that, while simple to apply, the proposed model can give better predictions of shear strength for RC short columns than other shear strength models available in the literature.
dc.publisherAmerican Society of Civil Engineers
dc.titleSplitting Failure of Reinforced Concrete Columns
dc.typeJournal Paper
dc.journal.volume140
dc.journal.issue3
dc.journal.titleJournal of Structural Engineering
dc.identifier.doi10.1061/(ASCE)ST.1943-541X.0000859
dc.treeJournal of Structural Engineering:;2014:;Volume ( 140 ):;issue: 003
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record