• Login
    View Item 
    •   DSpace Home
    • ASCE
    • Journal of Structural Engineering
    • View Item
    •   DSpace Home
    • ASCE
    • Journal of Structural Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Seismic Behavior of a Modern Concrete Coupled Wall

    Thumbnail
    View/Open
    %28asce%29st%2E1943-541x%2E0000896.pdf (7.139Mb)
    Date
    2013
    Author
    Dawn E.
    Lehman
    Jacob A.
    Turgeon
    Anna C.
    Birely
    Christopher R.
    Hart
    Kenneth P.
    Marley
    Daniel A.
    Kuchma
    Laura N.
    Lowes
    Metadata
    Show full item record
    Abstract
    RC core walls are used commonly in modern building construction as the primary lateral load–resisting system. To meet architectural constraints, including elevator, stair, and doorway openings, common configurations include walls coupled together with heavily reinforced, low-aspect-ratio coupling beams. Numerous studies have focused on coupling beams and improved seismic performance and design of coupling beams. However, far fewer research programs have studied the seismic behavior of the coupled wall system. Coupled walls are typically used in mid- to high-rise construction, and understanding their seismic response requires simulation beyond the coupling beam and must include all important yielding components of the system. A research project was undertaken to investigate the response of a midrise coupled wall designed to meet current codes. The advanced testing capabilities of the University of Illinois at Urbana-Champaign George E. Brown, Jr. Network for Earthquake Engineering Simulation (NEES) experimental facility were used to conduct a large-scale test of a coupled wall. The test specimen modeled the lower 3 stories of a 10-story building. The demands from the upper stories were imposed on each pier using an innovative loading device capable of imposing shear, moment, and axial loads or displacements. Damage progression included yielding of coupling beams, yielding of wall piers, spalling in the wall piers, and the coupling beams. Specimen failure occurred almost without warning at 2.27% drift, resulting in significant loss of lateral and axial load–carrying capacity. The damage sustained included concrete core crushing and longitudinal bar buckling in the compressive wall pier. These experimental results were combined with prior test data to develop improved design models for coupled wall systems.
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/68791
    Collections
    • Journal of Structural Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV