dc.description.abstractNodal T-connections made up of circular hollow section (CHS) braces and square hollow section (SHS) chords (CHS-SHS T-connections) have the advantage that they do not require complex brace end preparation when compared with CHS-CHS T-connections. The stress-concentration factors (SCFs) in CHS-SHS T-connections have also been found to be lower than those in SHS-SHS T-connections by previous researchers. At present, no parametric equations have been developed for determination of SCFs for the design of CHS-SHS T-connections. In this investigation, eight CHS-SHS T-connections with unique nondimensional parameters were strain gauged for determination of strain-concentration factors (SNCFs) and therefore SCFs. A three-dimensional finite-element model was then developed using the
dc.publisherAmerican Society of Civil Engineers
dc.titleStress-Concentration Factors in Circular Hollow Section and Square Hollow Section T-Connections: Experiments, Finite-Element Analysis, and Formulas
dc.typeJournal Paper
dc.journal.volume139
dc.journal.issue11
dc.journal.titleJournal of Structural Engineering
dc.identifier.doi10.1061/(ASCE)ST.1943-541X.0000759
dc.treeJournal of Structural Engineering:;2013:;Volume ( 139 ):;issue: 011