Show simple item record

dc.contributor.authorQiang
dc.contributor.authorXie
dc.contributor.authorLi
dc.contributor.authorSun
dc.date.accessioned2017-05-08T22:00:14Z
dc.date.available2017-05-08T22:00:14Z
dc.date.copyrightJune 2013
dc.date.issued2013
dc.identifier.other%28asce%29st%2E1943-541x%2E0000765.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/68652
dc.description.abstractTransmission tower collapses caused by strong winds or severe freezing rains frequently occur in many parts around the world. To study the mechanical behavior and failure mechanism of tower structures under such environmental loads, three pairs of tower subassemblages, including one single-panel pair and two double-panel pairs, were designed and statically tested at Tongji University. The difference between the two specimens in each pair was that one had an additional diaphragm as a method of retrofitting while the other did not. One pair of double-panel specimens was tested to simulate and capture the failure pattern of transmission towers subjected to wind load. Correspondingly, two pairs were used to investigate the relevant response of structures under the combination of vertical ice and wind loads. A comparative study on strains at critical sections and local and global deformations as well as failure modes of the tower subassemblages was carried out. The favorable effects of adding the diaphragm, in terms of improving the structural performance of the tower subassemblages, were emphasized in the study. The test results showed that the complex interaction between the main legs and the diagonal bracing members significantly affect the overall stability performance of the towers and their behavior at the ultimate limit state. The study demonstrated that the diaphragms comprehensively improved the mechanical behavior and increased the load-carrying capacity of the transmission tower structures. For specimens subjected to simulated wind load only, the bearing capacity increased by 22.1% after adding horizontal diaphragms. On the other hand, for double- and single-panel specimens subjected to simulated ice and wind loads, the corresponding increases were 17.6 and 18.3%, respectively. The implications of the test results and their relevant practical applications in the wind- and ice-resistant design of transmission towers are summarized and discussed in this paper.
dc.publisherAmerican Society of Civil Engineers
dc.titleExperimental Study on the Mechanical Behavior and Failure Mechanism of a Latticed Steel Transmission Tower
dc.typeJournal Paper
dc.journal.volume139
dc.journal.issue6
dc.journal.titleJournal of Structural Engineering
dc.identifier.doi10.1061/(ASCE)ST.1943-541X.0000722
dc.treeJournal of Structural Engineering:;2013:;Volume ( 139 ):;issue: 006
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record