| dc.description.abstract | ASCE 7 does not provide design wind loads for roof-mounted solar panels. This paper discusses the use of the wind tunnel test method, called Method 3 in ASCE 7-05, which was originally intended for obtaining design wind loads for individual buildings. Because roof-mounted solar arrays are generally mounted in many configurations on many buildings of many different shapes, additional requirements are necessary to use Method 3 in this situation. The paper describes these additional requirements. | |