    Cyclic Seismic Testing of Composite Concrete-Filled U-Shaped Steel Beam to H-Shaped Column Connections

    Thumbnail
    View/Open
    %28asce%29st%2E1943-541x%2E0000676.pdf (2.051Mb)
    Date
    2013
    Author
    Cheol-Ho
    Lee
    Hong-Gun
    Park
    Chang-Hee
    Park
    Hyeon-Jong
    Hwang
    Chang-Nam
    Lee
    Hyoung-Seop
    Kim
    Sung-Bae
    Kim
    Metadata
    Show full item record
    Abstract
    In this study, the cyclic seismic performance of a concrete-filled U-shaped steel beam to H-shaped steel column connections was experimentally evaluated. The concrete-filled U-shaped steel beams were compositely attached to the concrete floor slab. The test was conducted in two stages. The first testing program was carried out on one-sided moment connections to find the most promising connecting scheme. The strengthening scheme, or welding steel plates to the beam bottom flange with minimized stress concentration, was shown to be the most satisfactory, and it was used in the second-stage test on two full-scale cruciform specimens. Considering the unique constructional nature of the proposed composite connections, the critical limit states such as weld fracture, local buckling, concrete crushing, and rebar buckling were carefully addressed in designing specimens. Test results showed that the connection details and design procedures proposed in this study can successfully control the critical limit states mentioned previously. The proposed connection detail successfully pushed the plastic hinging to the tip of the strengthened zone as intended in design, thus effectively protecting the more vulnerable beam-to-column welded joint. The specimens typically exhibited a maximum story drift capacity of more than 5.5% rad, exceeding the minimum limit of 4% rad required of special moment frames. Four of the five specimens tested in this study eventually failed because of a low-cycle fatigue fracture across the beam bottom flange at a high story drift greater than 5.0% rad.
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/68559
    Collections
    • Journal of Structural Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV