dc.description.abstractThis paper investigates the effects of seismic retrofitting on the modal characteristics of a 6-story RC building located in Istanbul, Turkey. Ambient vibration surveys were carried out before, during, and after the retrofitting work, which took place between June and December 2010. The building was retrofitted via jacketing of columns, addition of structural walls, and construction of a mat foundation. These studies were complemented with data from forced vibration tests performed with an eccentric-mass shaker after the retrofitting work was completed. During retrofitting, partitions were demolished; as a result, the first modal frequency of the building decreased by 11%, based on the results of the ambient vibration survey. The ambient vibration survey also showed that the modal frequencies after the seismic retrofitting increased by almost 96%. During the forced vibration tests, the building was excited around its modal frequencies using an eccentric-mass shaker. It was found that the modal damping values increased with the amplitude of the excitation force.
dc.publisherAmerican Society of Civil Engineers
dc.titleAmbient and Forced Vibration Testing of a Reinforced Concrete Building before and after Its Seismic Retrofitting
dc.typeJournal Paper
dc.journal.volume139
dc.journal.issue10
dc.journal.titleJournal of Structural Engineering
dc.identifier.doi10.1061/(ASCE)ST.1943-541X.0000568
dc.treeJournal of Structural Engineering:;2013:;Volume ( 139 ):;issue: 010