Vierendeel Bending Study of Perforated Steel Beams with Various Novel Web Opening Shapes through Nonlinear Finite-Element Analyses
Abstract
The Vierendeel mechanism is always critical in perforated steel beams with single large web openings, where global shear forces and Vierendeel moments coexist. Thus far, the main parameters that affect the structural behavior of such beams are the depth of the web opening, the critical opening length of the top T-section, and the web opening area. A comprehensive finite-element (FE) study of four sizes of perforated steel sections with three different sizes of 11 standard and novel nonstandard web opening shapes was undertaken, and their primary structural characteristics are presented in detail to provide a simple design method for general practice. The different geometric parameters were isolated and studied to understand the significance of their effects and in turn advance the knowledge on the performance of perforated steel beams. An elaborate FE model was established, with both material and geometrical nonlinearity, allowing load redistribution across the web openings and formation of the Vierendeel mechanism. The reduction of the global shear capacities, because of incorporation of the local Vierendeel moments acting on the top and bottom T-sections, was obtained directly from the FE analysis. Following that, a comparison of the global shear-moment (