| dc.description.abstract | A high-performance wood-frame shear wall system, named the MIDPLY truss wall (MTW), was developed for application to midrise wood-frame buildings. The basic MTW system consists of metal-plate–connected wood trusses, sheathing panels, and steel tie-downs. The sheathing panels of the MTW system are placed between the wood trusses and connected with mechanical fasteners. The main concept of the MTW system is to increase the lateral load resistance of a shear wall by reconfiguring the wall frame members into lateral load–resisting wood trusses. In this study, the feasibility of the MTW system was investigated. Eight | |