    Numerical Modeling of Shear Behavior of Reinforced Concrete Pile Caps

    Thumbnail
    View/Open
    %28asce%29st%2E1943-541x%2E0000540.pdf (3.481Mb)
    Date
    2012
    Author
    Alan G. Bloodworth
    Jing Cao
    Ming Xu
    Metadata
    Show full item record
    Abstract
    The application of bending theory based methods and strut-and-tie models for the design of pile caps to resist shear is still a subject of debate, with the latest Eurocodes permitting both methods but not giving much guidance as to their use. The former UK design standards for concrete buildings and bridges, recently withdrawn, gave more guidance, and it is likely that these methods will continue to be used by designers. However, there is considerable discrepancy between these standards, particularly with regard to the width of cap over which shear enhancement at short spans may be applied, and how much longitudinal reinforcement to take as a tie in the strut-and-tie method. Both standards are also seen as conservative. To gain a better understanding of the problem and assess the available design methods, nonlinear finite-element analysis has been performed to investigate the shear behavior of four-pile reinforced concrete pile caps, under full-width wall loading. The models were validated against an experimental program that included an optical photogrammetric method for measuring full-field displacements. An extensive parametric study was carried out, varying shear span, cap width, and reinforcement ratio over a practical range. The conservatism of the UK design standards, and the real shear capacity of the pile caps were found to be a function of shear enhancement factor and the width of the cap over which shear enhancement is applied. Strut-and-tie behavior was observed in the models, and a commonly used strut-and-tie method was found to give fairly good predictions. A modified strut-and-tie method is suggested for this particular configuration of a four-pile cap under full-width loading, which gives more accurate predictions. This is especially so for samples with large transverse pile spacing, where a significant proportion of the longitudinal reinforcement over the width of the cap can be assumed to participate in the yielding ties.
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/68410
    Collections
    • Journal of Structural Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV