dc.contributor.authorGary S. Prinz
dc.contributor.authorPaul W. Richards
dc.date.accessioned2017-05-08T21:59:37Z
dc.date.available2017-05-08T21:59:37Z
dc.date.copyrightMarch 2012
dc.date.issued2012
dc.identifier.other%28asce%29st%2E1943-541x%2E0000514.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/68381
dc.description.abstractBraced frames are often used to resist lateral earthquake loads in steel buildings, but braces can interfere with architectural features. Eccentrically braced frames (EBFs) will accommodate windows, doors, and halls, but have performance limitations when link-to-column connections are required. An alternative to EBFs may be buckling-restrained braced frames with eccentric configurations (BRBF-Es). This paper introduces the concept of BRBF-Es and highlights design considerations. An analytical study was conducted that compares the performance and economy of BRBF-Es with EBFs. Results from non-linear time history analyses indicate that BRBF-Es will have greater residual drifts than comparable EBFs, but are less susceptible to failures at link-to-column connections. BRBF-Es require more steel than EBFs, but savings in design, fabrication, and erection may offset higher material costs.
dc.publisherAmerican Society of Civil Engineers
dc.titleSeismic Performance of Buckling-Restrained Braced Frames with Eccentric Configurations
dc.typeJournal Paper
dc.journal.volume138
dc.journal.issue3
dc.journal.titleJournal of Structural Engineering
dc.identifier.doi10.1061/(ASCE)ST.1943-541X.0000471
dc.treeJournal of Structural Engineering:;2012:;Volume ( 138 ):;issue: 003
dc.contenttypeFulltext