Show simple item record

dc.contributor.authorEri Gavanski
dc.contributor.authorGregory A. Kopp
dc.date.accessioned2017-05-08T21:59:29Z
dc.date.available2017-05-08T21:59:29Z
dc.date.copyrightDecember 2011
dc.date.issued2011
dc.identifier.other%28asce%29st%2E1943-541x%2E0000437.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/68302
dc.description.abstractDuration effects on the design wind loads for glass are examined with respect to ASCE 7-10. Pressure time histories are created by combining variations of wind speed and wind direction from a “design cyclone” with pressure coefficients obtained from wind tunnel tests of low-rise buildings. The results indicate that the assumption of a 3-s gust duration in ASCE 7-10 may underestimate appropriate values for design loads for glass, with the degree of underestimation varying, depending primarily on the probability of exceedence of the peak pressures. On the basis of these results, modifications to the peak pressures specified in ASCE 7-10 are suggested that maintain the time duration of 3-s, consistent with current glass-design provisions.
dc.publisherAmerican Society of Civil Engineers
dc.titleStorm and Gust Duration Effects on Design Wind Loads for Glass
dc.typeJournal Paper
dc.journal.volume137
dc.journal.issue12
dc.journal.titleJournal of Structural Engineering
dc.identifier.doi10.1061/(ASCE)ST.1943-541X.0000397
dc.treeJournal of Structural Engineering:;2011:;Volume ( 137 ):;issue: 012
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record