Show simple item record

dc.contributor.authorAndi Asiz
dc.contributor.authorIan Smith
dc.date.accessioned2017-05-08T21:59:25Z
dc.date.available2017-05-08T21:59:25Z
dc.date.copyrightNovember 2011
dc.date.issued2011
dc.identifier.other%28asce%29st%2E1943-541x%2E0000404.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/68265
dc.description.abstractThis paper discusses connections between Cross-Laminated-Timber (CLT) floor slabs and steel framework of hybrid tall buildings. Using the example of a 24-story building analysis, it is shown that such connections can be made using simple fasteners like large screws to enforce efficient diaphragm action in the critical case of CLT slabs subjected to lateral seismic or wind events. Results of laboratory tests on connections between CLT slabs and structural steel members are presented to prove this.
dc.publisherAmerican Society of Civil Engineers
dc.titleConnection System of Massive Timber Elements Used in Horizontal Slabs of Hybrid Tall Buildings
dc.typeJournal Paper
dc.journal.volume137
dc.journal.issue11
dc.journal.titleJournal of Structural Engineering
dc.identifier.doi10.1061/(ASCE)ST.1943-541X.0000363
dc.treeJournal of Structural Engineering:;2011:;Volume ( 137 ):;issue: 011
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record