Show simple item record

dc.contributor.authorBadr M. Abou-Zeid
dc.contributor.authorWael W. El-Dakhakhni
dc.contributor.authorA. Ghani Razaqpur
dc.contributor.authorS. Foo
dc.date.accessioned2017-05-08T21:59:24Z
dc.date.available2017-05-08T21:59:24Z
dc.date.copyrightOctober 2011
dc.date.issued2011
dc.identifier.other%28asce%29st%2E1943-541x%2E0000385.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/68245
dc.description.abstractNew standards for blast protection of buildings are currently being developed in the United States and Canada. In this regard, both standards are considering unreinforced masonry (URM) walls as particularly vulnerable to blast events and may not be used in blast-resisting structural systems. In this paper, the effectiveness of enforcing arching action as a cost-effective hardening technique for vertically spanning one-way URM walls under blast loads is investigated. A total of eight full-scale concrete-block URM walls were subjected to blast loads generated by high explosives. Enforcing URM walls arching between rigid supports significantly enhanced their out-of-plane blast resistance compared to similar nonarching (flexural) URM walls. Moreover, no fragments or debris were observed on the leeward side of the arching walls, indicating the potential of the proposed hardening technique in reducing the hazard level on the occupants of buildings with exterior URM walls. The improved performance is attributed to the formation of hinges at the walls’ supports and midheights. This three-hinged arch mechanism allowed the walls to develop large in-plane compressive forces, which subsequently increased their out-of-plane resistances and prevented flying debris due to increased friction forces between the masonry courses. Comparing the observed strength of the arched walls to their strength predicted by existing models showed a significant underestimation of the actual wall strengths. The results of the study clearly demonstrate that, with minimal structural intervention, URM walls can significantly improve the building envelope performance and contribute to the structural resistance of blast loads.
dc.publisherAmerican Society of Civil Engineers
dc.titleResponse of Arching Unreinforced Concrete Masonry Walls to Blast Loading
dc.typeJournal Paper
dc.journal.volume137
dc.journal.issue10
dc.journal.titleJournal of Structural Engineering
dc.identifier.doi10.1061/(ASCE)ST.1943-541X.0000344
dc.treeJournal of Structural Engineering:;2011:;Volume ( 137 ):;issue: 010
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)