    Experimental and Analytical Investigation of Concrete Filled Steel Tubular Columns

    Thumbnail
    View/Open
    %28asce%29st%2E1943-541x%2E0000361.pdf (2.599Mb)
    Date
    2011
    Author
    Zhijing Ou
    Baochun Chen
    Kai H. Hsieh
    Marvin W. Halling
    Paul J. Barr
    Metadata
    Show full item record
    Abstract
    In this paper, an experimental and analytical investigation of concrete-filled steel tubular (CFST) laced columns is presented. These columns consist of four concrete-filled steel tubes that are laced together. A total of 27 experimental tests were conducted to quantify the column failure mechanism at ultimate loads. The experiments were designed to obtain the load-deflection curves. These curves were subsequently used to quantify the structural behavior for each element of the hybrid column. Experimental results indicate that the compression force in the longitudinal members dominated the failure mechanism in the CFST columns. In-plane bending occurred when member segments reached the compression failure load. The forces in the lacing members (diagonal and horizontal bracing) were found to be small and remained in the elastic range through failure. The experimental study was used to validate an analytical parametric study. The analytical study showed that increasing slenderness ratios and eccentricities reduced the ultimate load capacity. Additionally, finite-element analyses of CFST columns based on four in situ structures were performed to determine the ultimate load-carrying capacity and were subsequently compared to several building codes. On the basis of the analytical results, a new methodology for calculating the ultimate load-carrying capacity is proposed. This purposed methodology is compared with five different building codes to quantify the increased accuracy.
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/68218
    Collections
    • Journal of Structural Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV