    System Identification Study of a 7-Story Full-Scale Building Slice Tested on the UCSD-NEES Shake Table

    Thumbnail
    View/Open
    %28asce%29st%2E1943-541x%2E0000340.pdf (1.477Mb)
    Date
    2011
    Author
    Babak Moaveni
    Xianfei He
    Joel P. Conte
    José I. Restrepo
    Marios Panagiotou
    Metadata
    Show full item record
    Abstract
    A full-scale 7-story reinforced concrete building slice was tested on the unidirectional University of California–San Diego Network for Earthquake Engineering Simulation (UCSD-NEES) shake table during the period from October 2005 to January 2006. A rectangular wall acted as the main lateral force resisting system of the building slice. The shake table tests were designed to damage the building progressively through four historical earthquake records. The objective of the seismic tests was to validate a new displacement-based design methodology for reinforced concrete shear wall building structures. At several levels of damage, ambient vibration tests and low-amplitude white noise base excitation tests were applied to the building, which responded as a quasi-linear system with dynamic parameters evolving as a function of structural damage. Six different state-of-the-art system identification algorithms, including three output-only and three input-output methods were used to estimate the modal parameters (natural frequencies, damping ratios, and mode shapes) at different damage levels based on the response of the building to ambient as well as white noise base excitations, measured using DC-coupled accelerometers. The modal parameters estimated at various damage levels using different system identification methods are compared to (1) validate/cross-check the modal identification results and study the performance of each of these system identification methods, and to (2) investigate the sensitivity of the identified modal parameters to actual structural damage. For a given damage level, the modal parameters identified using different methods are found to be in good agreement, indicating that these estimated modal parameters are likely to be close to the actual modal parameters of the building specimen.
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/68197
    Collections
    • Journal of Structural Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV