Show simple item record

dc.contributor.authorMichael P. Newcombe
dc.contributor.authorWouter A. van Beerschoten
dc.contributor.authorDavid Carradine
dc.contributor.authorStefano Pampanin
dc.contributor.authorAndrew H. Buchanan
dc.date.accessioned2017-05-08T21:59:09Z
dc.date.available2017-05-08T21:59:09Z
dc.date.copyrightNovember 2010
dc.date.issued2010
dc.identifier.other%28asce%29st%2E1943-541x%2E0000278.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/68130
dc.description.abstractRecent advances in multistory timber building design have led to new structural systems that allow open floor plans with large spans between frames and/or walls. Timber-concrete composite (TCC) flooring can achieve the spans required but has the potential to be flexible under diaphragm actions, which can significantly alter the seismic response of a building. In-plane experimental tests on a 3 m by 3 m one-third scale TCC floor were performed using quasi-static earthquake loading simulation. The experimental results indicate that the deformation between the floor and lateral load resisting systems (LLRS) is much greater than the in-plane deformation of the floor diaphragm. Hence, a floor system with similar aspect ratio can be modeled as a single-degree-of-freedom for future structural analyses. Different connections were considered between the floor unit and lateral restraints, which simulate the LLRS. The connection was either timber-to-timber or concrete-to-timber and incorporated screws or nails acting as dowels or inclined at 45°. Each connection type performed differently in terms of stiffness, strength, ductility capacity, and induced damage. Screws that were oriented at 45° to the connection interface were significantly stiffer than fasteners aligned orthogonal to the interface. There was little difference in the initial stiffness for the concrete-to-timber connection compared to the timber-to-timber connection. The testing indicated that a timber-to-timber interface is more desirable because of construction ease and reparability. The in-plane response of the floor system is modeled using finite elements and compared to experimental results. Design recommendations are provided for the cyclic strength of inclined wood fasteners.
dc.publisherAmerican Society of Civil Engineers
dc.titleIn-Plane Experimental Testing of Timber-Concrete Composite Floor Diaphragms
dc.typeJournal Paper
dc.journal.volume136
dc.journal.issue11
dc.journal.titleJournal of Structural Engineering
dc.identifier.doi10.1061/(ASCE)ST.1943-541X.0000239
dc.treeJournal of Structural Engineering:;2010:;Volume ( 136 ):;issue: 011
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record