Show simple item record

dc.contributor.authorJ. D. Ginger
dc.contributor.authorJ. D. Holmes
dc.contributor.authorP. Y. Kim
dc.date.accessioned2017-05-08T21:59:08Z
dc.date.available2017-05-08T21:59:08Z
dc.date.copyrightOctober 2010
dc.date.issued2010
dc.identifier.other%28asce%29st%2E1943-541x%2E0000264.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/68115
dc.description.abstractA dominant opening in a windward wall will generate large positive internal pressures during windstorms, which, in combination with large suction pressures on the roof, commonly causes building failures and is hence a governing design criterion. The fluctuating (and peak) internal pressures are dependent on the external pressure and the size of the opening and the size of the building volume. This study presents ratios of internal pressure to external pressure standard deviations and peaks in terms of the nondimensional opening size to volume parameter,
dc.publisherAmerican Society of Civil Engineers
dc.titleVariation of Internal Pressure with Varying Sizes of Dominant Openings and Volumes
dc.typeJournal Paper
dc.journal.volume136
dc.journal.issue10
dc.journal.titleJournal of Structural Engineering
dc.identifier.doi10.1061/(ASCE)ST.1943-541X.0000225
dc.treeJournal of Structural Engineering:;2010:;Volume ( 136 ):;issue: 010
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record