Show simple item record

dc.contributor.authorR. Parnell
dc.contributor.authorB. W. Davis
dc.contributor.authorL. Xu
dc.date.accessioned2017-05-08T21:59:02Z
dc.date.available2017-05-08T21:59:02Z
dc.date.copyrightJune 2010
dc.date.issued2010
dc.identifier.other%28asce%29st%2E1943-541x%2E0000209.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/68054
dc.description.abstractA study investigating the modal properties and dynamic response of several laboratory-constructed and in situ floors supported with cold-formed steel C-shaped joists for floors was conducted. The tested floors were typical of residential midrise applications, with oriented-strand board, FORTACRETE, and cold-formed steel deck subfloors, both with and without lightweight concrete topping. Details including span, large lip-reinforced web openings, subfloor, topping, strongback, and framing condition were varied to observe their influence on the fundamental frequency, damping ratio, and deflection. Suggestions for the design and remediation of floors where vibration serviceability is a concern are given. Laboratory tested floor systems were generally found to be the worst-case scenario for the natural frequency and damping ratio. Furniture and finishes were found to not appreciably change the performance of a floor system. The responses of the floor systems tested in this study were evaluated against the ISO 2631 limit for maximum acceleration and Onysko’s static deflection limit, as presented in
dc.publisherAmerican Society of Civil Engineers
dc.titleVibration Performance of Lightweight Cold-Formed Steel Floors
dc.typeJournal Paper
dc.journal.volume136
dc.journal.issue6
dc.journal.titleJournal of Structural Engineering
dc.identifier.doi10.1061/(ASCE)ST.1943-541X.0000168
dc.treeJournal of Structural Engineering:;2010:;Volume ( 136 ):;issue: 006
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record