    The monolithic structural action of various types of walls of flanged cross section and walls with engaged stiffeners or returns (nonrectangular sections) is critically dependent on the shear capacity of the interface between the components making up the section. An assessment of the shear capacity of the interface may also be required as part of the elastic or inelastic analysis of structural elements. Observation of past earthquake events has confirmed that effectively connected flanges also directly influence the seismic performance of nonrectangular sections by providing a more robust and seismically resistant structural element. To analyze the significance of the parameters that influence the vertical shear resistance of interfaces of flanged sections of masonry obtained using different types of bonding and bonding patterns (header units, shear connectors, and wire ties), a series of specimens with “H-shaped” cross sections was tested. The vertical shear capacity of the interface at the flange-web intersection was assessed in each case and compared to predicted code capacities. Considerable strength reserves and shear ductility were observed in almost all cases. Following the experimental study, a numerical investigation was carried out using a simplified micromodeling finite element approach. It showed that both the size of the specimen as well as the boundary and applied loading conditions on the flanges can significantly influence the observed vertical shear resistance of the interfaces of specimens with the same bonding pattern. Using the results of the numerical investigation, the critical parameters for a test to determine the vertical shear capacity of brick masonry nonrectangular cross sections are assessed and the governing parameters for a suitable shear test suggested.
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/68027
    Collections
    • Journal of Structural Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV