Show simple item record

dc.contributor.authorBenedikt Weber
dc.contributor.authorPatrick Paultre
dc.date.accessioned2017-05-08T21:58:57Z
dc.date.available2017-05-08T21:58:57Z
dc.date.copyrightMarch 2010
dc.date.issued2010
dc.identifier.other%28asce%29st%2E1943-541x%2E0000153.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/67996
dc.description.abstractThis paper presents a sensitivity-based damage identification of a three-dimensional truss tower tested in the laboratory. A finite-element model is updated by modal parameters obtained from ambient vibration measurements. The paper focuses on details of modeling and model updating. To get a realistic model, it was necessary to include eccentric connections, bending stiffness in truss members, and foundation flexibility. For model updating, a number of mathematical techniques are combined in a consistent way, including regularization of the nonlinear updating problem and its linearization. Considering all these details correctly, damage in the truss has been successfully identified. However, it is also demonstrated how neglecting some of these algorithmic details can lead to incorrect results. It is also shown how static condensation can lead to a model that is valid for the undamaged case but cannot adequately represent the damaged case.
dc.publisherAmerican Society of Civil Engineers
dc.titleDamage Identification in a Truss Tower by Regularized Model Updating
dc.typeJournal Paper
dc.journal.volume136
dc.journal.issue3
dc.journal.titleJournal of Structural Engineering
dc.identifier.doi10.1061/(ASCE)ST.1943-541X.0000105
dc.treeJournal of Structural Engineering:;2010:;Volume ( 136 ):;issue: 003
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record