Show simple item record

dc.contributor.authorYao Cui
dc.contributor.authorTakuya Nagae
dc.contributor.authorMasayoshi Nakashima
dc.date.accessioned2017-05-08T21:58:51Z
dc.date.available2017-05-08T21:58:51Z
dc.date.copyrightOctober 2009
dc.date.issued2009
dc.identifier.other%28asce%29st%2E1943-541x%2E0000097.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/67943
dc.description.abstractA series of shallowly embedded steel column base consisting of an exposed column base and a covering reinforced concrete floor slab were tested under horizontal cyclic loading to very large deformation. By adjustments to the floor slab thickness, shape, and reinforcing bars in the slab, the initial stiffness, maximum strength, and dissipated energy of the shallowly embedded column base increase significantly with respect to those of the exposed column base. It is found to be practical to strengthen the shallowly embedded column base so that it would behave like a fully embedded column base. Punching shear failure in the floor slab around the column due to the uplift of the base plate occurs when the shallowly embedded column base fails. Based on the plastic theory, a mechanical model that considers the contributions of the anchor bolts and the bearing and punching shear of the floor slab is proposed to evaluate the maximum strength. The evaluated results have good agreement with the test results, with errors not greater than 20%.
dc.publisherAmerican Society of Civil Engineers
dc.titleHysteretic Behavior and Strength Capacity of Shallowly Embedded Steel Column Bases
dc.typeJournal Paper
dc.journal.volume135
dc.journal.issue10
dc.journal.titleJournal of Structural Engineering
dc.identifier.doi10.1061/(ASCE)ST.1943-541X.0000056
dc.treeJournal of Structural Engineering:;2009:;Volume ( 135 ):;issue: 010
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record