Show simple item record

dc.contributor.authorW. F. Hunt
dc.contributor.authorJ. M. Hathaway
dc.contributor.authorR. J. Winston
dc.contributor.authorS. J. Jadlocki
dc.date.accessioned2017-05-08T21:48:38Z
dc.date.available2017-05-08T21:48:38Z
dc.date.copyrightJune 2010
dc.date.issued2010
dc.identifier.other%28asce%29he%2E1943-5584%2E0000180.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/63028
dc.description.abstractThe premise of low impact development (LID) is to reduce runoff volumes while simultaneously matching target (often predevelopment) infiltration and evapotranspiration volumes. Many structural practices used in LID, such as bioretention, infiltration trenches, and permeable pavement, require a seasonally high water table (SHWT) to be 1–2 m from the surface. Conversely, level spreader–vegetated filter strip systems can be implemented in locations where a SHWT would restrict the use of other practices. A 19.4 m long reinforced concrete level spreader upslope of a
dc.publisherAmerican Society of Civil Engineers
dc.titleRunoff Volume Reduction by a Level Spreader–Vegetated Filter Strip System in Suburban Charlotte, N.C.
dc.typeJournal Paper
dc.journal.volume15
dc.journal.issue6
dc.journal.titleJournal of Hydrologic Engineering
dc.identifier.doi10.1061/(ASCE)HE.1943-5584.0000160
dc.treeJournal of Hydrologic Engineering:;2010:;Volume ( 015 ):;issue: 006
dc.contenttypeFulltext