• Login
    View Item 
    •   DSpace Home
    • ASCE
    • Journal of Composites for Construction
    • View Item
    •   DSpace Home
    • ASCE
    • Journal of Composites for Construction
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Flexural Behavior of a Carbon Fiber–Reinforced Polymer Prestressed Decked Bulb T-Beam Bridge System

    Thumbnail
    View/Open
    %28asce%29cc%2E1943-5614%2E0000348.pdf (1.205Mb)
    Date
    2013
    Author
    Nabil Grace
    Kenichi Ushijima
    Prince Baah
    Mena Bebawy
    Metadata
    Show full item record
    Abstract
    Experimental and numerical investigations were conducted to evaluate the performance of a newly developed bridge system. Through the investigation, a decked bulb T-beam bridge model was constructed, instrumented, and tested under service and ultimate loads. The bridge model had a width of 2.59 m (8.5 ft), an effective span of 9.45 m (31 ft), a depth of 356 mm (14 in.), and was composed of five adjacent decked bulb T-beams. The T-beams were interconnected at their top flanges using 76-mm (3-in.)-wide ultra-high-performance concrete (UHPC) shear key joints and five full-depth equally spaced transverse diaphragms along the span. Each diaphragm was posttensioned with two nonbonded transverse carbon fiber composite cable (CFCC) strands. The investigation revealed that the developed decked bulb T-beam bridge system maintained its structural integrity under service loads with signs of distress in neither the shear key joints nor top flanges. UHPC shear keys with the transverse diaphragms were adequate to achieve monolithic action across the width of the bridge model. In addition, transverse posttensioning forces were effective in restoring the structural integrity of the bridge model when cracks were artificially induced in the shear key joints. At the ultimate limit state the bridge model exhibited compression failure by crushing of the concrete in the top flange. The compression failure was associated with low ductility, a dense cracking pattern, and excessive deflection.
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/57484
    Collections
    • Journal of Composites for Construction

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV