Show simple item record

dc.contributor.authorJ. F. Chen
dc.contributor.authorS. Q. Li
dc.contributor.authorL. A. Bisby
dc.date.accessioned2017-05-08T21:36:37Z
dc.date.available2017-05-08T21:36:37Z
dc.date.copyrightFebruary 2013
dc.date.issued2013
dc.identifier.other%28asce%29cc%2E1943-5614%2E0000317.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/57451
dc.description.abstractFiber reinforced polymer (FRP)-wrapped circular concrete columns under axial compression usually fail as a result of FRP rupture in the hoop direction. The average measured hoop strain in the FRP jacket at failure of such columns, i.e., the apparent FRP rupture strain, is typically considerably lower than the ultimate tensile strain obtained from tensile tests of flat coupons. A large scatter also exists in the measured rupture strains over the surface of an FRP-wrapped column at ultimate failure. No rational model based on sound theories is currently available to explicitly consider the reduction of the apparent FRP rupture strain in design. This paper discusses the possible failure modes of FRP-wrapped concrete columns and the factors that may play a role in the initiation of failure. Further research needs and the possible consequences for the optimized design of FRP-wrapped concrete columns are discussed.
dc.publisherAmerican Society of Civil Engineers
dc.titleFactors Affecting the Ultimate Condition of FRP-Wrapped Concrete Columns
dc.typeJournal Paper
dc.journal.volume17
dc.journal.issue1
dc.journal.titleJournal of Composites for Construction
dc.identifier.doi10.1061/(ASCE)CC.1943-5614.0000314
dc.treeJournal of Composites for Construction:;2013:;Volume ( 017 ):;issue: 001