Show simple item record

dc.contributor.authorT. J. Stratford
dc.contributor.authorL. A. Bisby
dc.date.accessioned2017-05-08T21:36:28Z
dc.date.available2017-05-08T21:36:28Z
dc.date.copyrightJune 2012
dc.date.issued2012
dc.identifier.other%28asce%29cc%2E1943-5614%2E0000263.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/57391
dc.description.abstractFiber-reinforced polymer (FRP) plate strengthening relies critically upon the adhesive that is used to bond it to the existing structure. A typical two-part ambient-cure epoxy adhesive for structural strengthening has a glass transition temperature of approximately 40°C–70°C, but the stiffness and strength of the adhesive typically decrease at temperatures somewhat below this characteristic temperature. This paper investigates the implications of the changes in adhesive properties at warm temperatures (
dc.publisherAmerican Society of Civil Engineers
dc.titleEffect of Warm Temperatures on Externally Bonded FRP Strengthening
dc.typeJournal Paper
dc.journal.volume16
dc.journal.issue3
dc.journal.titleJournal of Composites for Construction
dc.identifier.doi10.1061/(ASCE)CC.1943-5614.0000260
dc.treeJournal of Composites for Construction:;2012:;Volume ( 016 ):;issue: 003
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record