• Login
    View Item 
    •   DSpace Home
    • ASCE
    • Journal of Composites for Construction
    • View Item
    •   DSpace Home
    • ASCE
    • Journal of Composites for Construction
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Predicting the Response of FRP-Strengthened Reinforced-Concrete Flexural Members with Nonlinear Evolutive Analysis Models

    Thumbnail
    View/Open
    %28asce%29cc%2E1943-5614%2E0000217.pdf (1.321Mb)
    Date
    2011
    Author
    Antonio R. Marí
    Eva Oller
    Jesús M. Bairán
    Metadata
    Show full item record
    Abstract
    To design efficient and economical strengthening solutions, the structural performance before and after the intervention must be accurately evaluated. In the case of statically indeterminate structures or when the structure has suffered damage or deterioration, linear elastic analysis methods are not adequate to obtain the residual capacity and the structural effects of the intervention because of the nonlinear response of the structure. In such cases, refined analytical models able to capture the structural nonlinear behavior, the effects of previous damage, and those produced by any intervention are required to design safe and economical strengthening solutions. In this paper, a nonlinear and time-dependent evolutive analysis model, previously developed by the authors, is applied to the prediction of the response of fiber-reinforced polymer (FRP)-strengthened concrete structures in flexure. The model can take into account the structural effects of changes in geometry, structural scheme, material properties, and applied loads that may occur along the structure service life, including those attributable to strengthening. A criterion to predict peeling failure in FRP-strengthened beams on the basis of nonlinear fracture mechanics consisting in evaluating the maximum shear force that can be transmitted to the concrete by the FRP laminate between cracks or at the laminate end is incorporated in the model. Two previous experimental programs have been used to validate the model. First, four RC continuous beams, three of them strengthened with FRP laminates and tested to study the influence of the FRP arrangement, are analyzed. Second, two beams previously precracked owing to service loads and strengthened with FRP are analyzed under increasing load up to failure. In all cases, very good agreement between the theoretical and the experimental results is obtained in terms of deflections, strains, reactions, internal forces, and failure mode, showing the capabilities of the model to evaluate the efficiency of proposed strengthening solutions.
    URI
    http://yetl.yabesh.ir/yetl/handle/yetl/57340
    Collections
    • Journal of Composites for Construction

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV