Show simple item record

dc.contributor.authorJulio F. Davalos
dc.contributor.authorAn Chen
dc.contributor.authorBin Zou
dc.date.accessioned2017-05-08T21:36:17Z
dc.date.available2017-05-08T21:36:17Z
dc.date.copyrightJune 2011
dc.date.issued2011
dc.identifier.other%28asce%29cc%2E1943-5614%2E0000165.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl/handle/yetl/57283
dc.description.abstractThis paper reports on research investigating a nongrouted sleeve-type connection used to attach fiber-reinforced polymer (FRP) decks to steel girders. The connection system was investigated for stiffness, strength, fatigue resistance, and degree of composite action. Static and fatigue tests were conducted first at the component level on push-out specimens to obtain
dc.publisherAmerican Society of Civil Engineers
dc.titleStiffness and Strength Evaluations of a Shear Connection System for FRP Bridge Decks to Steel Girders
dc.typeJournal Paper
dc.journal.volume15
dc.journal.issue3
dc.journal.titleJournal of Composites for Construction
dc.identifier.doi10.1061/(ASCE)CC.1943-5614.0000162
dc.treeJournal of Composites for Construction:;2011:;Volume ( 015 ):;issue: 003
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record